POWER SUPPLY TRANSFORMERS

Power supply transformers with rated power output 1-1.5 VA 

Transformer design sketch 

Transformers are designed for use in electronic equipment.  Frequency:

Frequency: 50~60 Hz +-1%
Insulation electric resistivity: 10 MOhm
Insulating strength: 3750 V
Flame resistance UL - 94VO
Operating temperature range 0~60°C
Storage and hauling temperature : -60~+60°C
Part Type Input Voltage, V Rated loading output voltage, V Rated power output. VA Idle current. A Dimensions ODxIDxHT, mm Weight, g
67111.010 230 24 1 0,020 32х27х25 85
67111.010-01 220 12 1 0,020 32х27х25 85
67111.010-03 220 2х9 1 0,010 32х27х25 85
67111.010-04 220 24 1,2 0,015 32х27х25 85
67111.015 230 18 1,2 0,0065 32х27х25 85
67111.015-02 230 12 1 0,010 32х27х25 85
67111.015-03 230 9 1,5 0,018 32х27х25 85
67111.015-04 220 2х12 1,4 0,020 32х27х25 85
67111.015-05 220 18 1,4 0,020 32х27х25 85
67111.015-06 220 9 1 0,020 32х27х25 85
67111.015-07 220 6 1 0,020 32х27х25 85
67111.015-08 220 2х6 1 0,020 32х27х25 85

Power supply transformers with rated power output 2 VA

Transformer design sketch

Transformers are designed for use in electronic equipment and comply with GOST Р50267.0-92 class II.

 

Rated power: 2 VA
Frequency: 50~60 Hz +-1%
Insulation electric resistivity: 100 MOhm
Insulating strength: 2500 V
Flame resistance (special order): UL-94VO
Operating temperature range : 0~60°C
Storage and hauling temperature : -60~+60°C
Max. weight : 0,09 kg
Part type Input voltage. V Output voltage. V Load current. A Idle current. A
67111.004 220 2x10,5 0,03 0,020
67111.037 220 2x12 0,03 0,020
67111.015 230 18 0,065 0,020
67111.015-01 230 230 0,003 0,020
67111.015-02 230 12 0,05 0,020
67111.015-03 230 9 0,065 0,020
67111.010 23 24 0,04 0,020
67111.010-01 220 12 0,08 0,020
67111.010-02 24 48 0,002 0,020
67111.010-03 220 2x9 0,055 0,020
67111.010-04 220 24 0,05 0,020
67111.015-005 220 6 0,24 0,020
67111.015-006 220 7.5 0,165 0,020
67111.015-007 220 8 0,2 0,020
67111.015-008 220 12 0,125 0,020
67111.015-009 220 13 0,1 0,020
67111.015-010 220 15 0,1 0,020
67111.015-011 220 2x9 0,07 0,020
67111.015-012 220 5 0,2 0,020
    10 0,035  
67111.015-013 220 7 0,03 0,020
    2x14 0,015  
67111.015-014 220 4,8 0,2 0,020
    2x9 0,03  
67111.015-015 220 2x6 0,12 0,020
67111.015-016 220 9 0,03 0,020
    2x15 0,015  
67111.015-017 220 3 0,4 0,020
67111.015-018 220 9 0,16 0,020
67111.015-019 220 15,5 0,07 0,020
    6,5 0,13  
67111.015-020 220 2x8 0,15 0,020
67111.015-021 220 9 0,1 0,020
67111.015-022 220 13,5 0,1 0,020
67111.015-023 220 2x12 0,1 0,020
67111.015-024 220 2x15 0,05 0,020
67111.015-025 220 2,3 0,165 0,020
    14,5 0,025  
67111.015-026 220 2x6 0,16 0,020
67111.015-027 220 2x18 0,04 0,020
67111.015-028 230 17 0,06 0,020
67111.015-029 230 9 0,11 0,020
67111.015-030 220 2x10 0,03 0,010

Power supply transformers with rated power output 5 VA

Transformer design sketch 

Transformers are designed for use in electronic equipment and comply with GOST Р50267.0-92 class II.

Rated power: 5 VA
Frequency: 50~60 Hz +-1%
Insulation electric resistivity: 100 MOhm
Insulating strength: 2500 V
Flame resistance (special order): : UL-94VO
Operating temperature range : 0~60°C
Storage and hauling temperature : -60~+60°C
Max. weight : 0,19 kg

Max. number of output windings – 4.

Output voltage and current within designed power on customer’s demand.

 

Power supply transformers with rated power output 8 VA

Transformer design sketch 

Transformers are designed for use in electronic equipment and comply with GOST Р50267.0-92 class II.

Rated power: 8 VA
Frequency: 50~60Hz +-1%
Insulation electric resistivity: 100 MOhm
Insulating strength: 2500 V
Flame resistance (special order):  UL-94VO
Operating temperature range : 0~60°C
Storage and hauling temperature : -60~+60°C
Max. weight : 0,3 kg

Output voltage and current within designed power on customer’s demand.

 

Power supply transformers with rated power output 10, 15, 28 VA

Transformer design sketch 

Transformers are designed for use in electronic equipment and comply with GOST Р50267.0-92 class II.

Frequency: 50~60 Hz +-1%
Insulation electric resistivity: 100 MOhm
Insulating strength: 2500 V
Flame resistance (special order): UL-94VO
Operating temperature range : 0~60°C
Storage and hauling temperature : -60~+60°C

Output voltage and current within designed power on customer’s demand.

Part type Input voltage. V Idle current. A Max. power. VA Number of independent secondary windings Dimentions. mm Weight. kg
ТП 10 220 (2x110) or 230 (2х115) 0,025 10 5 69x58x21 0,29
ТП 15 220 (2x110) or 230 (2x115) 0,045 15 5 69x58x27 0,4
ТП 28 220 (2x110) 0,060 28 5 69x58x37 0,6

Transformers may be equipped with thermal switch (intervention temperature 105 – 135°C).

Power supply transformers with rated power output 25, 30, 40, 50, 60 VA

Transformers are designed to power the lighting fixtures and for use in a stabilized power supplies. Transformers’ primary winding contains a microrelay. activated at 125°C.

Frequency: 50-60 Hzц +-1%
Input voltage: 220 V, 230 V
Выходное напряжение при номинальной нагрузке: 12 V
Insulation electric resistivity: 10 MOhm
Insulating strength: 3750 V
Flame resistance : UL-94VO
Operating temperature range : 0~60°C
Storage and hauling temperature : -60°C ~ +60°C
Part type Rated power output, VA Max. load current, A Dimentions, mm Weight, kg
67111.064 25 1,6 150x50x40 1,0
67111.064-01 30 2,0 160x50x40 1,2
67111.064-02 40 2,6 170x50x40 1,3
67111.064-03 50 3,2 185x50x40 1,5
67111.064-04 60 4,0 225x50x40 2,0

TP60 2х100/2х20-2х10 V power supply transformers with rated power output 60 VA

Transformer design sketch 

Transformers are designed for use in electronic equipment and comply with GOST-14233-84.

Rated power output: 60 VA
Frequency: 50 Hz
Climatic version: MCC 4.2 GOST 15150-69
Insulation electric resistivity: 10 MOhm
 Insulating strength beetween 1 and 2 windings: 4000 V
Operating temperature range : 0~60°C
Storage and hauling temperature : -60~+60°C
Max. weight : 1,050 kg
Output No Input voltage, V Rated load current, A Idle current, A Output voltage, V Idle voltage, V
1 - 4; 9 - 12 110   0,06    
13 - 14   0,9   20 22
15 - 16   0,9   10 11
19 - 20   0,9   10 11
21 - 22   0,9   20 22

Power supply transformers with rated power output 250 VA 

Transformer design sketch

Operating conditions:

Climatic version: MCC 4.2 GOST 15150-69
High ambient temperature: 55°C
Overview:
Transformers weight, max: 2,7 kg
 Insulating strength, Veff :  
- Between secondary windings: 500
- Between secondary windings and the core: 500
Max. power output: 250 VA
Max. idle current: 0,12 A

Service consultation

The company's managers will be happy to answer your questions and calculate the cost of services and prepare an individual commercial offer.